Submersible drainage pump J 405
Submersible drainage pump J 405
Weight: 270 kg (595 lb)
Performance range – J405, 50 Hz
Performance range – J405, 60 Hz
Performance range – J405, 60 Hz US
Built-in thermal switches in the stator windings (140ºC /284ºF, ±5), connected to built-in contactor or to separate control box.
DI leakage sensor, but not in combination with built-in contactor.
4” (standard HD), 6”, 8” (standard ND) hose connections
4”, 6”, 8” G/B.S.P. threaded connections
4″, 6″, 8″ NPT threaded connections
Plug in without having to worry about overheating. Built-in contactor connected to the thermal sensors protects the motor from overheating.
One investment for years of cost-efficient pumping. Impeller in high chrome alloy steel ensures a long lifetime and high efficiency.
Double outer casing and good heat convection enable the pump to operate continuously at low levels or even run dry without damaging the motor.
Save time and money with easy on-site service. Modular design lowers the overall service costs. By removing the top cover of the pump, you can easily check the electrical junction box. Environmentally safe white oil is used in the oil casing for easy inspection of seal conditions.
Electric submersible pump | J 405 |
Maximum submergence | 20 m |
Protection class | IP 68 |
Max. temperature of pumped medium at max. power input and continuous duty | 40ºC |
Max. media density | 1,100 kg/m3 |
pH of the pumped medium | 5-8 |
Strainer hole | 8 x 34 mm |
Max number of starts | 30/hour |
Motor rating P2 | 35 kW |
Speed | 2,941 rpm |
Power cable | 20 m type H07RN8-F |
Electric submersible pump | J 405 |
Maximum submergence | 20 m |
Protection class | IP 68 |
Max. temperature of pumped medium at max. power input and continuous duty | 40ºC |
Max. media density | 1,100 kg/m3 |
pH of the pumped medium | 5-8 |
Strainer hole | 8 x 34 mm |
Max number of starts | 30/hour |
Motor rating P2 | 43 kW |
Speed | 3,537 rpm |
Power cable | 20 m type H07RN8-F |
Electric submersible pump | J 405 |
Maximum submergence | 65 ft |
Protection class | IP 68 |
Max. temperature of pumped medium at max. power input and continuous duty | 104ºF |
Max. media density | 0.0397 lb/inch3 |
pH of the pumped medium | 5-8 |
Strainer hole | 5/16″ x 1 5/16″ |
Max number of starts | 30/hour |
Motor rating P2 | 57 Hp |
Speed | 3,537 rpm |
Power cable | 65 ft type AWG |